Roofing Lead Roll Code 3

Roofing Lead Roll Code 3

Availability: In stock

DESCRIPTION

Roll cast lead has been in use in the construction industry for a wide variety of applications for many hundre...View the full description

Product Code

Description

Stock

Unit Of Sale

Product Variants

183011

Roofing Lead Roll Code 3 - 150mm wide 3-metre Long

Roofing Lead Roll Code 3 - 150mm wide 3-metre Long

Product Code

183011

Stock

3

Unit of Sale

PRICE Ex VAT

  • Buy 1 for £18.20

183201

Roofing Lead Roll Code 3 - 150mm wide 6-metre Long

Roofing Lead Roll Code 3 - 150mm wide 6-metre Long

Product Code

183201

Stock

1

Unit of Sale

PRICE Ex VAT

  • Buy 1 for £35.10

183013

Roofing Lead Roll Code 3 - 225mm wide 3-metre Long

Roofing Lead Roll Code 3 - 225mm wide 3-metre Long

Product Code

183013

Stock

0

Unit of Sale

PRICE Ex VAT

  • Buy 1 for £26.52

Out of stock

183203

Roofing Lead Roll Code 3 - 225mm wide 6-metre Long

Roofing Lead Roll Code 3 - 225mm wide 6-metre Long

Product Code

183203

Stock

0

Unit of Sale

PRICE Ex VAT

  • Buy 1 for £53.30

Out of stock

183014

Roofing Lead Roll Code 3 - 240mm wide 3-metre Long

Roofing Lead Roll Code 3 - 240mm wide 3-metre Long

Product Code

183014

Stock

0

Unit of Sale

PRICE Ex VAT

  • Buy 1 for £28.60

Out of stock

183204

Roofing Lead Roll Code 3 - 240mm wide 6-metre Long

Roofing Lead Roll Code 3 - 240mm wide 6-metre Long

Product Code

183204

Stock

0

Unit of Sale

PRICE Ex VAT

  • Buy 1 for £55.90

Out of stock

183016

Roofing Lead Roll Code 3 - 300mm wide 3-metre Long

Roofing Lead Roll Code 3 - 300mm wide 3-metre Long

Product Code

183016

Stock

1

Unit of Sale

PRICE Ex VAT

  • Buy 1 for £35.10

183206

Roofing Lead Roll Code 3 - 300mm wide 6-metre Long

Roofing Lead Roll Code 3 - 300mm wide 6-metre Long

Product Code

183206

Stock

3

Unit of Sale

PRICE Ex VAT

  • Buy 1 for £70.20

183021

Roofing Lead Roll Code 3 - 450mm wide 3-metre Long

Roofing Lead Roll Code 3 - 450mm wide 3-metre Long

Product Code

183021

Stock

0

Unit of Sale

PRICE Ex VAT

  • Buy 1 for £53.30

Out of stock

183211

Roofing Lead Roll Code 3 - 450mm wide 6-metre Long

Roofing Lead Roll Code 3 - 450mm wide 6-metre Long

Product Code

183211

Stock

2

Unit of Sale

PRICE Ex VAT

  • Buy 1 for £105.30

183026

Roofing Lead Roll Code 3 - 600mm wide 3-metre Long

Roofing Lead Roll Code 3 - 600mm wide 3-metre Long

Product Code

183026

Stock

1

Unit of Sale

PRICE Ex VAT

  • Buy 1 for £70.20

183216

Roofing Lead Roll Code 3 - 600mm wide 6-metre Long

Roofing Lead Roll Code 3 - 600mm wide 6-metre Long

Product Code

183216

Stock

2

Unit of Sale

PRICE Ex VAT

  • Buy 1 for £140.40
Product Description

DESCRIPTION

Roll cast lead has been in use in the construction industry for a wide variety of applications for many hundreds of years.  Architects, engineers, contractors & property-owners are attracted to it for its durability, flexibility (malleable), its’ superior corrosion-resistance and low maintenance requirements.  When installed correctly it provides a high visual aesthetic for both traditional and contemporary buildings.  Also known as milled lead, rolled lead is made by rolling a solid slab of lead between closing rollers on a rolling mill. Rolled lead sheet is usually made to BS EN 12588 specification.

Flashings can be formed around all areas where water ingress is high risk such as chimney base & rooftile abutments, roofing tiles and brickwork of a building. Due to the malleability of the material itself and the consistency of its thickness, correctly installed lead will move with a building, expanding and contracting, coping with the wide range of temperature fluctuations a building can experience. Flashings made from plastics and bitumen can be susceptible to cracking under UV-rays becoming brittle over time. This can lead to water ingress, damage to the roof structure itself, severely reduce K-value of the insulation and cause internal damage to the building. Flashings around chimneys, dormer or bay windows, parapet cappings, gutters, parapet gutters and valley gutters in particular are specifically designed to keep out water and should always be formed using a trusted and tested material that will not require maintenance or replacement for many years to come. Lead is by far the best material to install.

FEATURES AND BENEFITS 

  • Durable and Malleable
  • Maintenance free for many years
  • Can be used in a variety of roofing applications
  • Code 3: nominal weight of 15kg per m2.

What are the differences between the many types of ‘Codes’ of lead – what do they mean and what are they used for:

Code 3 Lead is 1.32mm thick (labelled Green) & has a nominal weight of 15.0Kg per m2 - Roll cast Lead flashing is used for soakers only.

Code 4 Lead is 1.80mm thick (labelled Blue) & has a nominal weight of 20.4Kg per m2 - Roll cast Lead flashing for soakers, flashings (Hip, Ridge, Apron, covers, Chimneys), pitched valley gutters, bay tops & canopies, dormers & vertical cladding.

Code 5 Lead is 2.24mm thick (labelled Red) & has a nominal weight of 25.4Kg per m2 Roll cast Lead flashing for flat & pitched roofing, soakers, flashings (Hip, Ridge, Apron, covers, Chimneys), pitched valley gutters, bay tops & canopies, parapet – box & tapered valley gutters, dormers & vertical cladding.

N.B. ALL LEAD WEIGHTS ARE SUBJECT TO A +/- 5% TOLERANCE

Do not forget to apply patination oil to all lead installations - Click Here to Buy Now!